Model No | UP6195A-72 | UP6195A-162 | |||||||
Inner chamber size(mm)W*H*D | 400×400×450 | 600×450×600 | |||||||
Exterior chamber size(mm)W*H*D | 1060×1760×780 | 1260×1910×830 | |||||||
Performance | Temperature range | -160℃,-150℃,-120℃,-100℃,-80℃,-70℃,-60℃,-40℃,-20℃,0℃~+150℃,200℃,250℃,300℃,400℃,500℃ | |||||||
Humidity range | 20%RH ~98%RH(10%RH ~98%RH or 5%RH ~98%RH) | ||||||||
Temp.&Humi fluctuation | ±0.2°C, ±0.5%RH | ||||||||
Temp.Humi.Uniformity | ±1.5°C; ±2.5%RH(RH≤75%),±4%RH(RH>75%)No-load operation,After stead state 30 min. | ||||||||
Temp.humi resolution | 0.01°C; 0.1%RH | ||||||||
20°C~High TempHeating up time | °C | 100 150 | |||||||
Min | 30 40 | 30 40 | 30 45 | 30 45 | 30 45 | 30 45 | |||
20°C~Low tempCooling down time | °C | 0 -20 -40 -60 -70 | |||||||
Min | 25 40 50 70 80 | ||||||||
Heating rate | ≥3°C/min | ||||||||
Cooling rate | ≥1°C/min | ||||||||
Material | Inner chamber material | SUS#304 stainless steel plate | |||||||
Exterior chamber material | Stainless steel plate+ powder coated | ||||||||
Insulation Material | PU & Fiberglass wool | ||||||||
System | Air circulation system | Cooling fan | |||||||
Fan | Sirocco fan | ||||||||
Heating System | SUS#304 stainless steel high-speed heater | ||||||||
Air flow | Forced Air Circulation(It enters at bottom and leaves at top) | ||||||||
Humidification system | Surface evaporation system | ||||||||
Refrigeration system | Imported compressor,French Tecumseh compressor or German Bitzer Compressor,finned type evaporator,air(Water)-cooling condenser | ||||||||
Refrigerating fluid | R23/ R404A USA Honeywell. | ||||||||
Condensation | Air(Water)-cooling condenser | ||||||||
Dehumidifying system | ADP critical dew point cooling/dehumidifying method | ||||||||
Controlling system | Digital electronic indicators+S.S.R.With PID automatic calculation capability | ||||||||
Operation interface | Grande Expertise in Temperature & Humidity Controller,Chinese-English Shift. | ||||||||
Controller | Programmable capability | Save 120 profiles with up to 1200 steps each | |||||||
Setting range | Temperature:-100℃+300℃ | ||||||||
Reading accuracy | Temperature:0.01℃ | ||||||||
Input | PT100 or T Sensor | ||||||||
Control | PID control | ||||||||
Communication interface | Equipped with standard communication interface devices USB,RS-232 and RS-485,enable the test chamber to be connected with personal computer(PC),to achieve multi-machine control and management at the same time.Standard: USB external memory port.Optional: RS-232, RS-485, GP-IB, Ethernet | ||||||||
Print function | Japan Yokogawa Temperature Recorder(Optional accessories) | ||||||||
Auxiliary | Limit Alarm,Self Diagnosis,Alarm Display(Failure Cause),Timing device(Automatic Switch) | ||||||||
Accessories | Multi-layer vacuum glass observation window,Cable port(50mm),Controlling status indicator lamp,Chamber light,Specimen loading shelf(2pcs,position adjustable),Guaze 5pcs,Operation manual 1 set. | ||||||||
Safety protection device | Over-heat protection circuit breaker,Compressor overload protection,Control system overload protection,Humidifying system overload protection,Overload indicator lamp. | ||||||||
Power supply | AC 1Ψ 110V;AC 1Ψ 220V;3Ψ380V 60/50Hz | ||||||||
Customized service | Welcome to Non-standard,Specail requirements,OEM/ODM orders. | ||||||||
The technical information will be subjected to change without notice |
UP-6195 Electronic Component Climate Resistance Test Chamber
Explore the {UP-6195 Electronic Component Climate Resistance Test Chamber}, a reliable and durable product from our factory. Conduct accurate climate resistance tests with ease. Order now!
Request a QuotePRODUCTS DETAILS
Hot Products
Contact us
Please feel free to give your inquiry in the form below We will reply you in 24 hours